Netgear's 700W Power Supply Unit for 8800 Series is fully-fault tolerant and load-sharing in an N+1 configuration. After the system is properly configured, if one PSU fails, the others will provide sufficient power to operate a fully loaded switch. The front panel contains two cooling fans. Airflow enters from the front vents on the PSU and exits to the rear vents of the switch. The AC input is located on the switch directly in back of each power supply bay. The front has a handle with a lever mechanism for insertion and removal.
Nominal Input |
100-240 V~, 60/50 Hz, 10 A max |
AC Voltage Input Range |
90-264 V~ |
Maximum Input Amperages |
7 A @ 200 V~ (high-line) 10 A @ 90 V~ (low-line) |
AC Line Frequency |
47 to 63 Hz |
AC Power Supply Input Socket |
IEC 320 C14 |
Minimum Wire Size |
16 AWG (1.0mm2) copper stranded (pre-approved cord set for country of use) |
DC Output |
48 V , 24 A/ 12 V , 4 A (high-line) 48 V , 13.5 A / 12 V , 4 A (low-line) |
DC Output Power (W) |
700 / 1200 W |
Operating Temperature |
32 to 104°F (0 to 40°C) |
Storage Temperature |
-40 to 158°F (-40 to 70°C) |
Operating Humidity |
10 to 95% relative humidity, non-condensing |
Operational shock |
30 m/s2 (3g) |